FMEA-004: Failed Update Without Rollback ¶
1 Status ¶
| Date | Status | |
|---|---|---|
| ▶ | 03-07-2026 | Identified |
2 Failure Mode ¶
An interrupted software update leaves the installation in a state that neither starts nor accepts a new update.
3 Effect ¶
The installation is unusable until manually reinstalled; on remote sites this means a service visit.
4 Cause ¶
The updater replaces files in place; a power loss or lost connection mid-update leaves a mixed installation, and no previous version is kept to fall back to.
5 Severity ¶
6 Occurrence ¶
7 Detection ¶
8 Mitigation ¶
Not yet defined; the analysis of an A/B installation scheme with automatic fallback is scheduled for the next iteration.
9 Monitoring ¶
Support tickets mentioning a failed update are tagged and reviewed weekly.